Our Testing Stories

Fastener load due to negative wind pressure

Unlike conventional unitized or stick framed curtainwalls, the fasteners for TingWall™ are not subjected to tension from negative wind load. The pressure is transferred directly to the vertical structural mullion through the engagement with the panel frame. Panel fasteners in shear are being used to support the individual panel dead weight only.








 
 
 
 
Other Stories
Two-story China Mock-up Test in China, 2002
Three-story mock-up test in Taiwan, 1997
Two-story mock-up test for Kossman Development Co. -for Omega Corporate Center
Building sidesway due to wind and seismic forces
Dead-Loaded Mullion / Floor Hanging Mullion
Two-story mock-up test at Architectural Testing Inc., 1994
Small-scale water test in Taiwan, 1995
 
 
 
  Some of products shown may be protected by one or more of the following U.S. Patents 5,452,552; 5,596,851; 5,598,671; 5,687,524, and foreign patents based on these U.S. patents. In addition, other related patents are pending. Rights to these patents are owned by Advanced Building Systems, Inc., Wilmington, DE, a wholly-owned subsidiary of TingWall Inc.