Please select the following stories to know more about our testing.
|
|
General Testing
|
A two story high, full scale TingWall™ mock-up was tested on October 22 and October 23 of 2002 at the Chinese government laboratory in Guangzhou in accordance with the requirements of Chinese Curtain Wall Standard GB/T 15227-94. The test results indicated that the performances are either the Top Grade or beyond the Standard requirement as itemized below in accordance with the sequence of tests. |
|
|
General Testing
|
|
- for Omega Corporate Center, tested by Farabaugh Engineering and Testing Inc. Turtle Creek, PA, 22 Feb. 1999 |
|
General Testing
|
|
Building sidesway due to wind or seismic forces has no effect on TingWall™. Individual panels are allowed to move independently from each other, and from the structural mullion support. Seismic movement is absorbed via the horizontal inter-panel movement. Sidesway/displacement is absorbed within the space of the Outer Airloop without pro ducing panel or sealant stress. TingWall™ is designed to absorb a wind or seismic induced story drift of 0.01 (L/100) times the story height without producing panel stress. This is more than adequate to satisfy the .0025 (L/400) deformation compatibility requirement specified in section 1633.2.4 of the 1997 Uniform Building Code. |
|
|
|
|
|
|